Background information: There are many cases where it is necessary to equip the ports of an interface card with different port models. It may for example be necessary to use COM1 as a 20mA programming interface for a PLC, as the software used only supports this port, while COM2 is connected to a serial RS232 mouse. For such requirements, W&T provides a very smart solution without any need for additional external hardware. The module concept of the serial W&T PC cards allow you to freely select the interface model, as the PC card mainboard is equipped with pluggable modules that convert the internal TTL signals into interface signals. The combined interface cards are supplied fully configured according to your specifications and are ready for installation. You can change a built-in port at any time by simply replacing the interface module.
Technical data:
Number of ports:
2 galvanically isolated slots for interface modules
UART:
16550 with FIFO
Base addresses:
03F8H, 02F8H, 03E8H, 02E8H
Interrupts:
IRQ 3..7, IRQ 9..12
Baud rate:
50..115,200 baud
Data format:
any format
Signal lines:
RxD,TxD,RTS,CTS,DSR,DCD,DTR,RI
Adapters:
12-pin header with 2mm spacing
Galvanic isolation:
Isolation voltage min. 1 KV DC between PC and serial ports
Power supply:
depending on applied module
Ambient temperature:
Storage: -40..+70°C, Operation: 0..+70°C
Permissible relative humidity:
0..95% RH (non-condensing)
Dimensions:
165 x 106 mm
Weight:
approx. 150 g
Delivery:
1x Serial ISA-Basic board, 1kV isolated
Special features:
Card may be fitted with plug-in modules of different interface types