Application: Connection of Centronics printers to IEEE488/GPIB interface
IEEE488 > Centronics interface
Product properties:
No special printers for measuring devices needed.
Simple installation
Configuration of address or
list-only mode available
Background information: Printers with Centronics interfaces are very popular and thus are available cheaply. With external interfaces, they can be adjusted to suit any port. The interface normally outlives several printer generations.
Technical data:
IEEE488 > Centronics interface, #32000
Primary address:
1.. 7 and list-only
Secondary address:
0.. 2
Components:
AH1, L1
Code conversion:
Commodore > GRASCII selectable by means of DIL switch or secondary address:
Power supply:
Supplied power adapter
Current consumption:
approx. 100 mA
Input:
24-pin Amphenol connector incl. 2m cable attached to the device
Output:
36-pin Centronics plug, interface Can directly be plugged onto the printer
Housing:
Plastic housing, 75x61x20 mm
Weight:
390 g incl. power adapter
Delivery:
1x HPIB > Centronics interface 1x power adapter for application in office