W&T Interfaces for TCP/IP, Ethernet, RS-232, RS-485, USB, 20mA Glass and plastic fiber optic, http, SNMP, OPC, I/O digital, I/O analog, ISA, PCI, ...? |
 |
|
 |
|
|
|
 |
Web-IO Universal
|
|

|
Web-IO application-ready
|
 |
Data Server |
 |
TCP/IP-Ethernet <> serial: Com-Server |
 |
USB, RS232, RS485, 20mA: Serial interfaces |
 |
Fiber optics, isolators and line drivers |
 |
PCI Express, PCI and ISA bus: PC cards |
 |
Printer interfaces |
 |
Accessories
Downloads
Old |
 |
Your shopping basket |
|
|
| |
 |
| Technical knowledge |
 |
Books, articles, glossaries...
Technical background info |
Applications for Com-Server, USB Server, Web-IO,
Web Thermometer and
Motherbox |
|
|
|
| |
Data sheet:
Web-Thermograph Pt100 / Pt1000
Product properties:
- Monitor temperatures and curves with your browser
- HTML page design user-variable
- Direct access to current temperature value, e.g., for integration into other Web pages
- SNMP temperature polling /Alarm traps for incorporating into your existing SNMP management system
- A new measurement is available every 4 seconds!
- Time synchronization via time server calibration
Technical data:
| Temperature sensor: |
|
Pt100/Pt1000 connection |
| Network: |
|
10/100BaseT autosensing
IPv6 on request |
| Supply voltage: |
|
12-24V AC / DC using screw terminal |
| |
| Measuring unit |
|
|
| Sensor: |
|
Pt100/Pt1000 connection, 2-, 3- or 4-wire |
| Measuring range: |
|
W&T sensor: -50°C...180°C PT100/PT1000 measuring input: -200°C...650°C |
| Resolution: |
|
1/10°C |
Maximum measuring error: Measuring unit |
|
| |
±0.3°C, ±0.2% |
 |
|
| PT100/1000 Sensor Class A |
|
| |
±0.15°C, ±0.2% |
 |
|
| Storage frequency: |
|
1, 5, 15, 60 min |
| Memory depth (832k): |
|
min. 14 weeks, max. 16 years |
| Deviation of the internal clock: |
|
max. 4.32 min. / month (without time server calibration) max. 3 sec. (with time server calibration) |
| |
|
|
| Other data |
|
|
| Measuring frequency: |
|
4 seconds |
| Galvanic isolation: |
|
Measurement inputs to network: min. 500V |
| E-mail function: |
|
Mail for sending alarms or as reporting function |
| Supply voltage: |
|
DC 12V .. 48V (+/-10%) AC 9Veff (-5%) - 24Veff (+5%) |
| Current consumption: |
|
AVG: 200mA @12VDC, 100mA @24VDC, 100mA @20VAC Max: 240mA @12VDC |
| Configuration interface: |
|
RS232 serial port, 9600 baud, 8 data bits, 1 stop bit, no parity |
| Housing: |
|
Plastic compact housing, 105x75x22mm |
| Weight: |
|
approx. 200g |
| Ambient storage temperature: |
|
-40..+70°C |
| Ambient operating temperature: |
|
0 .. +60°C |
| Delivery: |
|
1x Web-Thermograph for top-hat rail mount 1x Pt100 sensor
Please order power supplies separately as accessories |
| |
 |
|
Wish for something! Your suggestions for improvement and additions |
| Web-Thermograph Pt100, 10/100BT, 24V with German Web interface |
57610 |
298.00 |
 |
|
| Web-Thermograph Pt100, 10/100BT, 24V with English Web interface |
57610_TB900662 |
298.00 |
 |
|
| Power supplies (please order as needed as accessories) |
| Plug-in Power Supply, 24V / 220mA DC with Euro connector |
11020 |
19.00 |
 |
| Plug-in Power Supply, 24V / 625mA DC with Euro, US and UK plugs |
11024 |
34.00 |
 |
Power Supply for DIN rail mount, 24V / 4.2A DC (merchandise, 2-year manufacturer’s guarantee) |
11077 |
89.00 |
 | | Measuring - Accessories |
| Pt-100 outdoor sensor, 4-wire, IP65 |
57014 |
48.00 |
 |
Factory calibrated, 1x 3 temperature points for complete unit with calibration certificate (This article cannot be ordered as a sample.) |
57013 |
198.00 |
 | | Mechanical Accessories |
| Mounting bracket for wall mounting |
58812 |
9.98 |
 |
| 19" DIN rail |
58813 |
19.00 |
 | | Software |
| WuTility |
00104 |
free |
Download |
| OPC Server |
00103 |
free |
Download |
| Sensobase® |
00107 |
free |
Download |
|
|
| |
|
|
| We are here for you personally! |
Wiesemann & Theis GmbH |
Tel.: +49 202/2680-110 (M-F 8:00 - 5:00) |
| Porschestr. 12 |
fax: +49 202/2680-265 |
| 42279 Wuppertal |
Individual e-mail |
|
|
© Wiesemann & Theis GmbH, subject to error and alteration: Since we can make errors, none of our statements should be used without verification. Please report any mistakes or misunderstandings so that we can be aware of them and respond appropriately as quickly as possible.
|
|
|
|
|