W&T Interfaces for TCP/IP, Ethernet, RS-232, RS-485, USB, 20mA Glass and plastic fiber optic, http, SNMP, OPC, I/O digital, I/O analog, ISA, PCI, ...?
Web-IO Universal
Digital
Analog
Web-IO application-ready
Monitor climate
Alarm Reporting Center
Web-Count / S0 acquisition
IP monitoring
Data Server
Motherbox 2
pure.box 2
Network Memory
TCP/IP-Ethernet servers
Com-Server (serial)
USB Server
Serial interfaces
USB, RS232, RS485, 20mA
Isolators & fiber optics
USB, RS232, RS485, 20mA
PC cards
PCI Express, PCI and ISA bus
...
Printer interfaces
Accessories
Downloads
Old
Your shopping basket
Search
Technical knowledge
Books, articles, glossaries...
Technical background info
Applications for Com-Server , USB Server , Web-IO ,
Web Thermometer ,
Motherbox and pure.box
Data sheet:
Web-IO Logger 6xDigital Input, 6xDigital Output
Control, monitor and acquire digital signals and document up to a million switching or counting events over time.
One box for any application:
Small System The onboard Web server allows you to configure and monitor the Web-IO Logger directly from the browser. Direct access to the outputs over the Web interface is also possible. Additional functions such as e-mail alarm or download of the logger data in an Excel-compatible file format enable stand-alone applications right out of the box.
Big System Standard protocols and interfaces such as OPC, SNMP, SYSLOG and AJAX enable trouble-free integration into existing systems. Even direct network access via TCP/IP sockets from individual applications is supported.
Web-IO Logger 6x6 Digital, #57650
Everything at a glance - monitor and switch directly from your browser
IO and counter data over time
Product properties:
Network connection:
10/100BaseT autosensing, RJ45
PoE (Power-Over-Ethernet):
Phantom power using data pairs
Power provided by unused wire pairs (spare-pair power)
Supply voltage from external power supply:
Supply from external power supply possible as an alternative to PoE
Web-based management
Configuration of the system parameters
Self-updating view of the input/output states and counters
Switching the outputs directly from the Web interface
Definition of alarm conditions
12 freely configurable alarms
Triggers: Inputs, outputs and counter states as well as time-based alarm intervals
Alarm options: E-mail, SNMP trap, UDP and TCP client, Syslog messages, FTP
6 digital outputs using industry-standard 6V-30V for local alarming
Current sourcing FET
Short-circuit-protected by virtue of thermal safety fuse
6 digital industry-standard inputs usable as signal and acknowledgement inputs
Type 1, current sinking in accordance with IEC 1131-2
Galvanically isolated in 2 groups
Protected against polarity reversal
Counter function
Event storage in internal data logger
8MB non-volatile memory, up to 1,000,000 switching and counting events
Consistent recording of data records using battery-backed clock
Recording of input, output and alarm events and counter states
Store max. 10 events per second
Logger processing on integrated Web server
Running software packet in each Web browser (no installation! No plug-in!)
Self-updating view of the current states of inputs, outputs and counters
Table view of any desired time windows from the data logger
Export any data logger time windows into CSV files
Online Web interface language selection
Conforms to standards both in office and industrial environments:
Increased noise immunity for industrial areas
Stricter noise emission for residential and commercial areas
Technical data:
Network:
10/100BaseT autosensing, RJ45
Alarms:
12 alarms for local and/or remote messaging
Response times:
Data and switching traffic: typically 12 ms
Digital outputs:
6 x Digital Out 6V-30V, 500mA
Short-circuit-protected
Digital inputs:
6 x Digital In,
max. input voltage +/-30V
protected against reverse connection within this range
Switching threshold 8V +/- 1V
"On" current = 2.2 mA
Adapters:
2x screw terminal for power (alternative to POE) 16x screw terminal for I/Os
Galvanic isolation:
Digital-IO’s - Network: min. 1000 V
Serial port:
RS232 interface as an optional configuration access.
LEDs:
- Status of the network connection - Current IO state - Device status
Power supply:
Power-over-Ethernet (PoE) or via screw terminal with DC 24V-48V (+/-10%) or AC 18Veff-30Veff (+/-10%)
Storage temperature:
-25°C-70°C
Operating temperature:
0°C-55°C when not row mounted 0°C-50°C when row mounted
Housing:
Plastic housing for DIN rail mount
105x45x75mm (l x w x h)
Weight:
approx. 200g
Delivery:
1 x Web-IO Digital Logger incl. Alarm-Management-Software 1 x Quick Guide 1 x W&T product CD
Wish for something!Your suggestions for improvement and additions
Web-IO 6x Digital Input, 6x Digital Output Logger
57650
398.00
Power supplies (please order as needed as accessories)
Plug-in Power Supply, 24V / 220mA DC with Euro plug
11020
19.00
Plug-in Power Supply, 24V / 625mA DC with Euro, US and UK plug
11024
34.00
Power Supply for DIN rail mount, 24V / 4.2A DC (merchandise, 2-year manufacturer’s guarantee)
11077
89.00
Coupling relays
230V coupling relay for Web-IO Digital - 1 x changeover for DIN rail mount
57015
19.80
230V coupling relay for Web-IO Digital - 2 x changeover for DIN rail mount
57016
19.80
Mechanical Accessories
19" DIN rail
58813
19.00
IP wall mount housing, 180 x 130 x 175 mm
11120
49.00
Storage and Visualization
Motherbox 2
50502
298.00
SD Data Station
50541
198.00
FTP Data Station 2
50542
198.00
Software
WuTility
00104
free
Download
LabVIEW Driver
00106
free
Download
OPC Server
00103
free
Download
We are here for you personally!
Wiesemann & Theis GmbH
Tel. : +49 202/2680-110 (M-F 8:00 - 5:00)
Porschestr. 12
fax : +49 202/2680-265
42279 Wuppertal
Individual e-mail
© Wiesemann & Theis GmbH, subject to error and alteration: Since we can make errors, none of our statements should be used without verification. Please report any mistakes or misunderstandings so that we can be aware of them and respond appropriately as quickly as possible.