Data sheet:
Web-IO Analog-In 2x 0..10V
Article no.: 57643
This article has been replaced by the expanded successor model Web-IO 4.0 Analog 0-10V.
Gather, monitor and archive analog measurement values over the Internet/Intranet
Properties
General information
- Monitor measured values and trends from a browser
- HTML page design user-variable
- Direct access to the actual value, e.g., for integration into other Web pages
- Graphic display of the stored temperature values
- Chart display
- Interactive display, user-scalable
- Display of limit violations
- Freely selectable line color
- E-mail for alarm or reporting functions
- SNMP measurement queries / alarm traps for incorporating into your existing SNMP management system
- Querying measured data with OPC
- Sensing alarms via syslog, TCP, SNMP, e-mail
- Archiving via FTP and W&T database tool Sensobase®
- Time synchronization using time server calibration
- Adapters:
- 10/100MBit
- 2x 0..10V voltage input
- Easy Start:
- Connect measurement lines and network cable
- Connect supply voltage
- Assign IP number
- That’s it!
- Software interfaces
- HTTP, Web browser
- AJAX, JavaScript and Java applet
- TCP and UDP sockets, client and server
- OPC server
- SMTP (e-mail)
- SNMP (including trap)
- SYSLOG
- FTP (data logging)
-
Conforms to standards both in office and industrial environments:
- High noise resistance per EN 61000-6-2
- Low noise emission per EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3
- 5 year guarantee
Technical data
- Voltage input:
- 2x 0..10V, 1MOhm
- Network:
- 10 / 100BaseT autosensing
- IPv6 on request
- Measuring unit
- Resolution
- 2x voltage input: 1.25mV
- Measuring error:
- max. 0.5% FSR (Full Scale Range 0..10V) TA = 0-60°C
- Storage frequency:
- 1, 5, 15, 60 min
- Memory depth (832k):
- min. 79 days, max. 17 years
- Deviation of the internal clock:
- max. 4.32 min. / month (without time server calibration)
- max. 3 sec. (with time server calibration)
- Measurement value acquisition (can be polled over the network and can generate alarms if desired):
- 2/second
- Saving in the internal data logger
- 1/Minute
- Other data
- Galvanic isolation:
- Measurement inputs to network: min. 500 volts
- E-mail function:
- Mail for sending alarms or as reporting function
- Supply voltage (uses screw terminals):
- DC 12V .. 48V (+/-10%)
- AC 12Veff .. 30Veff (+/-10%)
- Current consumption:
- AVG: 185mA @12VDC, 90mA @24VDC
- Housing:
- Plastic compact housing, 105x75x22mm
- Weight:
- approx. 200g
- Ambient storage temperature:
- -40 .. +70°C
- Ambient operating temperature:
- 0 .. +60°C
- Scope of delivery:
- 1x Web-IO Analog-In 2x 0..10V
- for DIN rail mount
- 1x product CD with
- WuTility management tool, OPC server,
- programming examples for VB/Delphi, SNMP-MIB,
- reference manual in German/English
Please order power supplies separately as accessories