Interfaces for TCP/IP, Ethernet, RS-232, RS-485, USB, 20mA, glass and plastic fiber optic cable, http, SNMP, OPC, Modbus TCP, I/O digital, I/O analog, ISA, PCI
Data sheet:

Web-Count 6x Digital

Web-based Pulse count acquisition with reporting, operation from the browser and data logging.

Count pulses from up to six signal sources. Send event- or time-triggered reports with information about the current counter states by FTP or by mail for example. The browser-based operating software for the device’s own Web server allows you to always keep the counter states in view and read out the built-in data logger for analysis and archiving purposes. This Smart Meter means nothing will escape your attention!

Properties

Interfaces:

  • Ethernet 10/100BaseT autosensing, RJ45
  • Galvanic isolation between the ports
    • Isolation voltage min. 1000V between digital inputs and network

Management and connectivity:

  • NEW: Use the Web-Counter as an hours of operation counter
  • Web-based management
    • Configuration of the system parameters
    • Definition of reports for counter state reporting
  • 12 freely configurable reports
    • Triggers: Each digital signal generator (input signal), counter states or time-triggered
    • Reporting: E-Mail, SNMP Trap, UDP- and TCP Client, Syslog Messages, FTP
  • 6 digital industry-standard inputs as signal input
    • Type 1, current sinking in accordance with IEC 1131-2
    • galvanically isolated in 2 groups
    • Polarity reversal protected
    • Counter function (32-bit)
    • Supports S0 pulse generators
  • Event storage in internal data logger
    • 8MB non-volatile memory (approx. 1,000,000 counter events)
    • Consistent recording of data records using battery-backed clock
    • Recording of input and counter states
    • Changed counter value saved every 100ms
  • Operating software on integrated Web server
    • Running software packet in each Web browser (no installation! No plug-in!)
    • Self-refreshing display of current counter states
    • Display of the logger contents
    • Export any data logger time windows into CSV files
  • Online Web interface language selection
    • Deutsch
    • English

Power supply:

  • PoE (Power-Over-Ethernet):
    • Phantom power using data pairs
    • Power provided by unused wire pairs (spare-pair power)
  • Supply voltage from external power supply:
    • Supply from external power supply possible as an alternative to PoE

Standards & more

  • Conforms to standards both in office and industrial environments:
    • High noise resistance per EN 61000-6-2
    • Low noise emission per EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3
  • 5 year guarantee

Worth knowing

Detect pulse counts from sensors:
The Web-Count 6x Digital makes it possible for you to acquire pulse counts from sensors with switching outputs and record them in the internal data memory with a time stamp.

With the Web-based operating software on the internal Web server you have full access to the device function from any browser in the network:

  • Monitor absolute and relative counter states
  • Read out the data logger (see Screenshots)
  • Export the stored data (Destination: *.CSV file)
  • Monitor utilization of the data memory

The software is self-refreshing, so that pages do not need to be reloaded in order to update the display. No installation or additional plugin is needed for running.

Once the device has received an IP address corresponding to your network, further parameter setting is also Web-based using configuration pages in the internal Web server.

Reports can be sent event- or time-triggered through a TCP/IP based network. The following methods are available:

  • Mail
  • SNMP trap
  • FTP
  • Syslog messages
  • TCP and UDP client

These reports can provide the reporting time, the current status of the counters and the state of the six digital inputs. The texts can be formulated individually.

User interface


Technical data

Connections and displays:

  • Network:
  • Digital counter inputs:
    • 6 x Digital In,
  • Serial port:
    • RS232 interface as an optional configuration access.
  • Adapters:
    • 2x screw terminal for power (alternative to POE)
    • 8x screw terminal for digital inputs
  • Reports:
    • 12 reports for messaging over the network
  • Response times:
    • Data exchange: typ. 12ms
    • max. input voltage +/-30V
    • protected against reverse connection within this range
    • Switching threshold 8V +/- 1V
    • "On" current = 2.2mA
    • integrated 32-bit counter
  • Counting frequency:
    • 1000 edges or 500 pulses per second
  • Galvanic isolation:
    • Digital inputs - network: min. 1000V
  • Supply voltage:
    • Power-over-Ethernet (PoE) or via screw terminal with
    • DC 24V-48V (+/-10%) or AC 18Veff-30Veff (+/-10%)
  • Current consumption:
    • PoE Class 1 (0.44W - 3.84W)
    • typ. 125mA@24V DC
  • Displays:
    • 1 LED Status
    • 1 LED Power
    • 1 LED Error

Housing and other data:

  • Housing:
    • Plastic housing for DIN rail mount
    • 105 x 45 x 75mm (L x W x H)
  • Enclosure rating:
    • IP20
  • Weight:
    • approx. 190g
  • Ambient temperature:
    • Storage: -25 ... +70°C
    • Operating: 0 ... 55°C when not row mounted
    • 0 ... 50°C when row mounted
  • Scope of delivery:
    • Web-Count 6x Digital
    • Quick Guide
    • W&T product CD
Up