Web-Thermometer Air Quality

  • Monitor temperatures, relative humidity and air quality

Monitor air quality

On-demand ventilation control in office buildings, schools, education and centers and sports facilities often involve measurement of CO2. But a drawback of CO2 measurement is that odors caused by VOC are not detected, since they have only a slight effect on the CO2 measurements.
Even though there is an actual ventilation need, this condition is not detected using traditional technology. With this VOC measuring instrument the room air quality can be determined based on human perception.

More information on VOC can be found here

Properties

Sensor:

  • Temperature sensor:
    • Measuring range: -40°C...85°C
  • Relative humidity sensor:
    • Measuring range 0..100% RH, permissible ambient: 0..95% (non-condensing)
  • Air quality sensor:
    • Measuring range: 0...60,000 ppb TVOC

Connectivity:

  • Configurable LED tower on sensor for optical indication of limit values
  • Monitor temperatures and trends from a browser
  • Alarm and reporting function:
    • E-mail for alarm or reporting functions
    • SNMP polling / alarm traps
    • Configure up to 12 alarm messages
  • Dynamic integration into other Web sites:
    • Direct access to current measurement values, e.g. JavaScript (AJAX).
  • Current Industry 4.0 protocols:
    • REST and MQTT support
  • Additional software interfaces for incorporating into your systems/databases:
    • SNMPv1, SNMPv2c, SNMPv3
    • Modbus-TCP
    • OPC server
    • Syslog
    • Sensobase (database integration via ODBC)
    • TCP and UDP sockets, client and server
    • FTP (data logging)
  • Possible applications:
    • Monitor temperatures in the server room, network cabinet or office
    • Logging of measurements via FTP, Excel file, email attachment and internal memory
    • dew point measurement, climate monitoring
    • Green IT: Monitor efficiency of the server room climate control

Data logger:

  • Internal data logger
    • Memory capacity: min. 7 weeks, max. 20 years
    • Save frequency: 15, 30 sec, 1, 5, 15, 60 min
  • Document measurement data online in the W&T Cloud and access from anywhere in the world
  • Internal clock
    • Time synchronization using time server calibration
    • Battery-backed device clock

Standards & more

  • optional: ISO factory calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified documentation of the measured value deviations
    • Valid for 12 months
  • optional: DAkkS/DKD calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified traceability to national standards
    • Valid for 12 months
  • Supply voltage via Power-over-Ethernet (PoE)
    • Phantom power using data pairs
    • Power over unused wire pairs
    • External power supply is an alternative
  • Conforms to standards both in office and industrial environments:
    • High noise resistance per EN 61000-6-2
    • Low noise emission per EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3
  • 5 year guarantee

Technical data

Connections and displays:

  • Combined sensor:
    • Temperature, relative humidity, air quality measurement
    • DB9 receptacle
    • Cable length: 2m (can be extended to max. 7m)
  • Network:
  • Galvanic isolation:
    • Network connection min. 1500 V
  • Supply voltage:
    • Power-over-Ethernet (PoE) or
    • DC 12V .. 48V (+/-10%)
  • Supply connection:
    • Plug-in screw terminal, 5.08mm spacing
    • Labeled "L+" and "M"
  • Current consumption:
    • PoE Class 1 (0.44 - 3.84W)
    • typ. 60mA @24V DC with external supply
  • Indicators:
    • 1 LED power
    • 2 LEDs network status
    • 4 LEDs status and error
    • 3 LEDs traffic-light display in sensor

Measuring unit:

  • Measuring range:
    • 0°C..85°C, 5..95% RH, 0-60,000 ppb TVOC
  • Resolution:
    • 1/10 °C, 1/10% RH, 1/10 ppb TVOC
  • Display variables:
    • °Celsius, °Fahrenheit, °Kelvin,
      %relative humidity, abs. humidity g/m³, dew point °C,
      mixing ratio g/kg, enthalpy kJ/kg

  • Air quality sensor:

    • TVOC based on ethanol

  • Measuring error:

    • Temperature:
    • typ. @ 25°C ±0.3°C
    • max. @ 0..50°C ±0.7°C
    • Long-term stability: typ. <0.03°C / year

    • Relative humidity:
    • typ. @ 25°C ±2% RH
    • max. @ 0..50°C ±4% RH (0-100% RH)
    • Long-term stability: typ. <0.25% RH / year

    • Air quality:
    • typ. @ 25°C ±15% of the measured value
    • max. ±40% of the measured value
    • Long-term stability: typ. <1.3% of the measured value

  • Measuring frequency:

    • 4s
  • Storage frequency:
    • 15s, 30s, 1m, 5m, 15m, 60m
  • Memory depth (4MB):
    • min. 7 weeks, max. 20 years

Housing and other data:

  • Housing:
    • Plastic compact housing for top-hat rail mount
    • 105x22x75mm (LxWxH)
  • Enclosure rating:
    • IP20
  • Weight:
    • approx. 200g
  • Ambient temperature
    • Storage: -40..+70°C
    • Operating: Non-contiguous mounting: 0 .. +60°C
    • contiguous mounting: 0 .. +50°C
  • Permissible relative humidity:
    • 0..95% RH (non-condensing)
  • Scope of delivery:
    • 1x Web-Thermometer Air Quality for DIN rail mounting
    • 1x W&T sensor, 2m (temperature/humidity & TVOC)
    • 1x Quick Guide